<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>University of Isfahan</PublisherName>
				<JournalTitle>Computational Intelligence in Electrical Engineering</JournalTitle>
				<Issn>2821-0689</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2020</Year>
					<Month>03</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Current Only Directional Over-Current Relays Using Teager Energy Operator</ArticleTitle>
<VernacularTitle>Current Only Directional Over-Current Relays Using Teager Energy Operator</VernacularTitle>
			<FirstPage>95</FirstPage>
			<LastPage>110</LastPage>
			<ELocationID EIdType="pii">24415</ELocationID>
			
<ELocationID EIdType="doi">10.22108/isee.2019.117901.1254</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Hadieh Sadat</FirstName>
					<LastName>Hosseini</LastName>
<Affiliation>Dept. of Electrical Engineering, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Amangaldi</FirstName>
					<LastName>Koochaki</LastName>
<Affiliation>Dept. of Electrical Engineering, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Hossein</FirstName>
					<LastName>Hosseinian</LastName>
<Affiliation>Dept. of Electrical Engineering, Amir Kabir University of Technology, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>07</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		<Abstract>Directional overcurrent relays utilize the voltage phasor as a reference for determining the direction of the fault. This requires measuring both current and voltage and makes the directional overcurrent relays more costly than the non-directional type. In this paper, a new method for detection the fault occurrence and fault direction is proposed, that is based on Teager energy operator. Teager energy operator is a simple algorithm that is used to signal processing and extraction of instantaneous changes in amplitude and frequency of a signal. To this end, the proposed algorithm uses only three consecutive samples of measured current signal for detection of fault and its direction. This method does not require phasor estimation and complex calculations. In addition, the method is very fast. This Algorithm is implemented and verified for different types of fault and several conditions using Matlab/Simulink. The simulation results show that the proposed method is fast and has acceptable accuracy.</Abstract>
			<OtherAbstract Language="FA">Directional overcurrent relays utilize the voltage phasor as a reference for determining the direction of the fault. This requires measuring both current and voltage and makes the directional overcurrent relays more costly than the non-directional type. In this paper, a new method for detection the fault occurrence and fault direction is proposed, that is based on Teager energy operator. Teager energy operator is a simple algorithm that is used to signal processing and extraction of instantaneous changes in amplitude and frequency of a signal. To this end, the proposed algorithm uses only three consecutive samples of measured current signal for detection of fault and its direction. This method does not require phasor estimation and complex calculations. In addition, the method is very fast. This Algorithm is implemented and verified for different types of fault and several conditions using Matlab/Simulink. The simulation results show that the proposed method is fast and has acceptable accuracy.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Teager Energy Operator</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fault Detection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fault Direction Detection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Directional Over Current Relays</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Current-Only Directional Relays</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://isee.ui.ac.ir/article_24415_538ee42ff2a44ee77f02f7e341093176.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
